LV Power cable insulation line

The line addresses the biggest low voltage power cables. All thermoplastic materials, flame retardant HFFR compounds, dry-silane cross-linked PE and in particular liquid silane technology can be processed with this versatile line, with the appropriate screw.
The extruder group is composed of the main extruder for insulation TR.100 25D, TR.120 25D or TR.160 25D and auxiliary extruder TR.45.V 24D or TR.60 25D for skin/stripe. An additional sheathing extruder can be tandemized with the insulation extruder group upon request. The main extruder is recommended 30D if liquid silane technology is used, to ensure PE grafting and peroxide decomposition and then high cross-linked degree with minimum silane dosage. For a multipurpose line where PVC, HFFR and liquid silane XLPE are processed, a standard 25D extruder is used with a special screw profile for liquid silane XLPE and an additional low compression screw for HFFR. The material handling station unit includes a gravimetric dosing unit for the optimal liquid silane dosage.

TYPICAL PRODUCT DESIGN
Conductor (solid and stranded) 1.5÷120 mm²
Max diameter over insulation 20 mm
Insulation material Thermoplastics
HFFR, cross-linked HFFR
XLPE
Liquid silane XLPE
Dry silane XLPE
Max setting speed 500 m/min

 

TYPICAL PRODUCT DESIGN
Conductor (solid and stranded) 6÷300 mm²
Max diameter over insulation 30 mm
Insulation material Thermoplastics
HFFR, cross-linked HFFR
XLPE
Liquid silane XLPE
Dry silane XLPE
Max setting speed 300 m/min

 

TYPICAL PRODUCT DESIGN
Conductor (solid and stranded) 10÷630 mm²
Max diameter over insulation 50 mm
Insulation material Thermoplastics
HFFR, cross-linked HFFR
XLPE
Liquid silane XLPE
Dry silane XLPE
Max setting speed 200 m/min